438 Series

Optical Wavelength Meter by Bristol Instruments

Note: Your Quotation Request will be directed to Bristol Instruments.

The 438 Series Multi-Wavelength Meter from Bristol Instruments operates from 1000 to 1680 nm covering C,L,T and O optical bands. It can simultaneously measure the wavelength, power, and signal to noise ratio (OSNR) of up to 1000 discrete optical signals. The device can measure wavelength to an accuracy as high as ± 0.3 pm and power is measured to an accuracy of ± 0.5 dB. The 438 system automatically calculates OSNR to greater than 40 dB. It has a high sensitivity of -40 dBm with automatic gain control and has fastest measurement rate of 10 Hz for reduced testing times. The convenient touch-screen display reports measurement data in a variety of formats. It has a warm up time of less than 15 minutes. The wavelength meter is available in a system that measures  89 mm x 432 mm x 381 mm and weighs 7.65 kg.

Two versions of the 438 Multi-Wavelength Meter are available. The model 438A is the most accurate, measuring wavelength to ± 0.3 pm. For less exacting test requirements, the model 438B is a lower-priced alternative with a wavelength accuracy of ± 1.0 pm.

 Product Specifications

    Product Details

    • Part Number :
      438 Series
    • Manufacturer :
      Bristol Instruments
    • Description :
      Accurate, Reliable, and Fastest multi-wavelength meter for WDM test applications.

    Fiber Parameters

    • Fiber Core Diameter :
      9/125 µm
    • Fiber Mode :
      Single Mode

    Applications

    • Application :
      WDM test applications

    Connections & Interface

    • Connector :
      FC/UPC
    • Interface :
      USB 2.0, Gigabit Ethernet, GPIB

    Temperature

    • Operating Temperature display :
      15 to 30 Degree C
    • Storage Temperature :
      -10 to 70 Degree Cv

    General Parameters

    • Operation Mode :
      CW Lasers
    • Wavelength Range :
      1270 to 1680 nm
    • Wavelength Display Unit :
      nm, cm-1, THz
    • Wavelength accuracy :
      ± 0.2 ppm to ± 1.0 pm at 1550 nm
    • Measurement Range :
      10 Hz
    • Measurement Time :
      0.1 s
    • Input Power Range :
      10 to 18 dBm
    • Power Calibration Accuracy :
      ± 0.5 dB(±30 nm from 1310 to 1550 nm)
    • Power Flatness :
      ± 0.2 dB
    • Power Linearity :
      ± 0.3 dB
    • Power Measurement Unit :
      dBm, mW, µW
    • Power Polarization Dependency :
      ± 0.5 dB
    • Power Requirements :
      90 to 264 VAC, 47 to 63 Hz, 80 VA max
    • Pressure :
      500 to 900 mm Hg
    • Relative Humidity :
      90% (Non- Condensation)
    • Return Loss :
      35 to 50 dB
    • S/N Ratio :
      35 to 50 dB
    • Sensitivity :
      -30 to 40 dBm
    • Warm up time :
      15 minutes
    • Wavelength Calibration :
      Continuous - built-in standard HeNe laser
    • Wavelength Display Resolution :
      0.00001 nm to 0.0001 nm

    Physical Properties

    • Dimensions :
      89 x 432 x 381 mm (3.5 x 17.0 x 15.0 inch)
    • Weight :
      17 lbs (7.65 kg)